SUMMARY:

This notice amends the Conforming Products List for instruments that conform to the Model Specifications for Evidential Breath Testing Devices (58 FR 48705).

EFFECTIVE DATE:

July 21, 2000.

Start Further Info

FOR FURTHER INFORMATION CONTACT:

Dr. James F. Frank, Office of Traffic Injury Control Programs, Impaired Driving Division (NTS-11), National Highway Traffic Safety Administration, 400 Seventh Street, SW, Washington, D.C. 20590; Telephone: (202) 366-5593.

End Further Info End Preamble Start Supplemental Information

SUPPLEMENTARY INFORMATION:

On November 5, 1973, the National Highway Traffic Safety Administration (NHTSA) published the Standards for Devices to Measure Breath Alcohol (38 FR 30459). A Qualified Products List of Evidential Breath Measurement Devices comprised of instruments that met this standard was first issued on November 21, 1974 (39 FR 41399).

On December 14, 1984 (49 FR 48854), NHTSA converted this standard to Model Specifications for Evidential Breath Testing Devices, and published a conforming Products List (CPL) of instruments that were found to conform to the Model Specifications as Appendix D to that notice (49 FR 48864).

On September 17, 1993, NHTSA published a notice (58 FR 48705) to amend the Model Specifications. The notice changed the alcohol concentration levels at which instruments are evaluated, from 0.000, 0.050, 0.101, and 0.151 BAC, to 0.000, 0.020, 0.040, 0.080, and 0.160 BAC; added a test for the presence of acetone; and expanded the definition of alcohol to include other low molecular weight alcohols including methyl or isopropyl. On June 4, 1999, the most recent amendment to the Conforming Products List (CPL) was published (64 FR 30097), identifying those instruments found to conform with the Model Specifications.

Since the last publication of the CPL, two (2) instruments have been evaluated and found to meet the model specifications, as amended on September 17, 1993, for mobile and Start Printed Page 45420non-mobile use. They are: (1) Intoxilyzer 400PA manufactured by CMI, Inc. of Owensboro, KY. This device is a hand-held breath tester with a fuel cell alcohol sensor. (2) Alco Sensor IV-XL manufactured by Intoximeters, Inc. of St. Louis, MO. This device is a hand-held breath tester with a fuel cell alcohol sensor that is microprocessor controlled. It is designed to minimize operator involvement in performing the test and processing the test data.

The CPL has been amended to add these two instruments to the list.

In accordance with the foregoing, the CPL is therefore amended, as set forth below.

Start Printed Page 45421

Conforming Products List of Evidential Breath Measurement Devices

Manufacturer and modelMobileNonmobile
Alcohol Countermeasure Systems Corp., Mississauga, Ontario, Canada:
Alert J3AD*XX
PBA3000CXX
BAC Systems, Inc., Ontario, Canada: Breath Analysis Computer*XX
CAMEC Ltd., North Shields, Tyne and Ware, England: IR Breath Analyzer*XX
CMI, Inc., Owensboro, KY:
Intoxilyzer Model:
200XX
200DXX
300XX
400XX
400PAXX
1400XX
4011*XX
4011A*XX
4011AS*XX
4011AS-A*XX
4011AS-AQ*XX
4011 AW*XX
4011A27-10100*XX
4011A27-10100 with filter*XX
5000XX
5000 (w/Cal. Vapor Re-Circ.)XX
5000 (w3/8″ ID Hose option)XX
5000CDXX
5000CD/FG5XX
5000ENXX
5000 (CAL DOJ)XX
5000VAXX
PAC 1200*XX
S-D2XX
Decator Electronics, Decator, IL: Alco-Tector model 500*X
Draeger Safety, Inc., Durango, CO:
Alcotest Model:
7010*XX
7110*XX
7110 MKIIIXX
7110 MKIII-CXX
7410XX
7410 PlusXX
Breathalyzer Model:
900*XX
900A*XX
900BG*XX
7410XX
7410-IIXX
Gall's Inc., Lexington, KY: Alcohol Detection System-A.D.S. 500XX
Intoximeters, Inc., St. Louis, MO:
Photo Electric Intoximeter*X
GC Intoximeter MK II*XX
GC Intoximeter MK IV*XX
Auto Intoximeter*XX
Intoximeter Model:
3000*XX
3000 (rev B1)*XX
3000 (rev B2)*XX
3000 (rev B2A)*XX
3000 (rev B2A) w/FM option*XX
3000 (Fuel Cell)*XX
3000 D*XX
3000 DFC*XX
AlcomonitorX
Alcomonitor CCX
Alco-Sensor IIIXX
Alco-Sensor IVXX
Alco-Sensor IV-XLXLX
Alco-Sensor AZXX
RBT-AZXX
RBT IIIXX
RBT III-AXX
RBT IVXX Start Printed Page 45422
RBT IV with CEM (cell enhancement module)XX
Intox EC/IRXX
Portable Intox EC/IRXX
Komyo Kitagawa, Kogyo, K.K.:
Alcolyzer DPA-2*XX
Breath Alcohol Meter PAM 101B*XX
Lifeloc Technologies, Inc., (formerly Lifeloc, Inc.), Wheat Ridge, CO:
PBA 3000BXX
PBA 3000-P*XX
PBA 3000CXX
Alcohol Data SensorXX
PhoenixXX
Lion Laboratories, Ltd., Cardiff, Wales, UK:
Alcolmeter Model:
300XX
400XX
AE-D1*XX
SD-2*XX
EBA*XX
Auto-Alcolmeter*X
Intoxilyzer Model:
200XX
200DXX
1400XX
5000 CD/FG5XX
5000 ENXX
Luckey Laboratories, San Bernadino, CA:
Alco-Analyzer Model:
1000*X
2000*X
National Draeger, Inc., Durango, CO:
Alcotest Model:
7010*XX
7110*XX
7110 MKIIIXX
7110 MKIII-CXX
7410XX
7410 PlusXX
Breathalyzer Model:
900*XX
900A*XX
900BG*XX
7410XX
7410-IIXX
National Patent Analytical Systems, Inc., Mansfield, OH:
BAC DataMaster (with or without the Delta-1 accessory)XX
BAC Verifier Datamaster (with or without the Delta-1 accessory)XX
DataMaster cdm (with or without the Delta-1 accessory)XX
Omicron Systems, Palo Alto, CA:
Intoxilyzer Model:
4011*XX
4011AW*XX
Plus 4 Engineering, Minturn, CO: 5000 Plus4*XX
Seres, Paris, France:
Alco MasterXX
AlcoproXX
Siemans-Allis, Cherry Hill, NJ:
Alcomat*XX
Alcomat F*XX
Smith and Wesson Electronics, Springfield, MA:
Breathalyzer Model:
900*XX
900A*XX
1000*XX
2000*XX
2000 (non-Humidity Sensor)*XX
Sound-Off, Inc., Hudsonville, MI:
AlcoDataXX
Seres Alco MasterXX
Seres AlcoproXX
Stephenson Corp.: Breathalyzer 900*XX
U.S. Alcohol Testing, Inc./Protection Devices, Inc., Rancho Cucamonga, CA:
Alco-Analyzer 1000X Start Printed Page 45423
Alco-Analyzer 2000X
Alco-Analyzer 2100XX
Verax Systems, Inc., Fairport, NY:
BAC Verifier*XX
BAC Verifier DatamasterXX
BAC Verifier Datamaster II*XX
*Instruments marked with an asterisk (*) meet the Model Specifications detailed in 49 FR 48854 (December 14, 1984) (i.e., instruments tested at 0.000, 0.050, 0.101, and 0.151 BAC.) Instruments not marked with an asterisk meet the Model Specifications detailed in 58 FR 48705 (September 17, 1993), and were tested at BACs = 0.000, 0.020, 0.040, 0.080, and 0.160. All instruments that meet the Model Specifications currently in effect (dated September 17, 1993) also meet the Model Specifications for Screening Devices to Measure Alcohol in Bodily Fluids.
Start Signature

(23 U.S.C. 402; delegations of authority at 49 CFR 1.50 and 501.1)

Issued on: July 17, 2000.

Rose A. McMurray,

Associate Administrator for Traffic Safety Programs.

End Signature End Supplemental Information