This site displays a prototype of a “Web 2.0” version of the daily
Federal Register. It is not an official legal edition of the Federal
Register, and does not replace the official print version or the official
electronic version on GPO’s govinfo.gov.
The documents posted on this site are XML renditions of published Federal
Register documents. Each document posted on the site includes a link to the
corresponding official PDF file on govinfo.gov. This prototype edition of the
daily Federal Register on FederalRegister.gov will remain an unofficial
informational resource until the Administrative Committee of the Federal
Register (ACFR) issues a regulation granting it official legal status.
For complete information about, and access to, our official publications
and services, go to
About the Federal Register
on NARA's archives.gov.
The OFR/GPO partnership is committed to presenting accurate and reliable
regulatory information on FederalRegister.gov with the objective of
establishing the XML-based Federal Register as an ACFR-sanctioned
publication in the future. While every effort has been made to ensure that
the material on FederalRegister.gov is accurately displayed, consistent with
the official SGML-based PDF version on govinfo.gov, those relying on it for
legal research should verify their results against an official edition of
the Federal Register. Until the ACFR grants it official status, the XML
rendition of the daily Federal Register on FederalRegister.gov does not
provide legal notice to the public or judicial notice to the courts.
Notice
Enter a search term or FR citation e.g.
88 FR 38230 FR 78782024-13208USDA09/05/24RULE0503-AA39SORN
Choosing an item from
full text search results
will bring you to those results. Pressing enter in the search box
will also bring you to search results.
Choosing an item from
suggestions
will bring you directly to the content.
This table of contents is a navigational tool, processed from the
headings within the legal text of Federal Register documents.
This repetition of headings to form internal navigation links
has no substantive legal effect.
Public Comments
Enhanced Content - Public Comments
This feature is not available for this document.
Regulations.gov Data
Enhanced Content - Regulations.gov Data
Additional information is not currently available for this document.
Document page views are updated periodically throughout the day and are
cumulative counts for this document. Counts are subject to sampling,
reprocessing and revision (up or down) throughout the day.
Page views
17
as of
10/15/2026 at 6:15 am EDT
Other Formats
Enhanced Content - Other Formats
This document is also available in the following formats:
This document has been published in the Federal Register. Use the PDF linked in the document sidebar for the official electronic format.
The following parties have filed petitions to modify the application of existing safety standards under section 101(c) of the Federal Mine Safety and Health Act of 1977.
1. Jim Walter Resources, Inc.
Jim Walter Resources, Inc., P.O. Box 133, Brookwood, Alabama 35444 has filed a petition to modify the application of 30 CFR 75.503 (Permissible electric face equipment; maintenance) to its No. 4 Mine (MSHA I.D. No. 01-01247) located in Tuscaloosa County, Alabama. The petitioner requests a modification of the existing standard to allow use of extended length cables on underground coal mining equipment. The petitioner proposes to use the extended length cable to power 2,400-volt continuous mining machines. The petitioner has listed in this petition for modification specific terms and conditions that would be followed when its proposed alternative method is implemented. The petitioner asserts that the proposed alternative method would provide at least the same measure of protection as the existing standard.
2. Jim Walter Resources, Inc.
Jim Walter Resources, Inc., P.O. Box 133, Brookwood, Alabama 35444 has filed a petition to modify the application of 30 CFR 75.1002 (Location of trolley wires, trolley feeder wires, high-voltage cables and transformers) to its No. 4 Mine (MSHA I.D. No. 01-01247) located in Tuscaloosa County, Alabama. The petitioner proposes to use 2,400-volt high-voltage trailing cable to power a continuous miner inby the last open crosscut and within 150 feet of pillar workings. The petitioner has listed in this petition for modification specific terms and conditions that would be followed when its proposed alternative method is implemented. The petitioner asserts that the proposed alternative method would provide at least the same measure of protection as the existing standard.
Request for Comments
Persons interested in these petitions are encouraged to submit comments via e-mail to comments@msha.gov, or on a computer disk along with an original hard copy to the Office of Standards, Regulations, and Variances, Mine Safety and Health Administration, 1100 Wilson Boulevard, Room 2352, Arlington, Virginia 22209. All comments must be postmarked or received in that office on or before September 11, 2003. Copies of these petitions are available for inspection at that address.
( printed page 47946)
Dated at Arlington, Virginia this 5th day of August 2003.
Marvin W. Nichols, Jr.,
Director, Office of Standards, Regulations, and Variances.