This site displays a prototype of a “Web 2.0” version of the daily
Federal Register. It is not an official legal edition of the Federal
Register, and does not replace the official print version or the official
electronic version on GPO’s govinfo.gov.
The documents posted on this site are XML renditions of published Federal
Register documents. Each document posted on the site includes a link to the
corresponding official PDF file on govinfo.gov. This prototype edition of the
daily Federal Register on FederalRegister.gov will remain an unofficial
informational resource until the Administrative Committee of the Federal
Register (ACFR) issues a regulation granting it official legal status.
For complete information about, and access to, our official publications
and services, go to
About the Federal Register
on NARA's archives.gov.
The OFR/GPO partnership is committed to presenting accurate and reliable
regulatory information on FederalRegister.gov with the objective of
establishing the XML-based Federal Register as an ACFR-sanctioned
publication in the future. While every effort has been made to ensure that
the material on FederalRegister.gov is accurately displayed, consistent with
the official SGML-based PDF version on govinfo.gov, those relying on it for
legal research should verify their results against an official edition of
the Federal Register. Until the ACFR grants it official status, the XML
rendition of the daily Federal Register on FederalRegister.gov does not
provide legal notice to the public or judicial notice to the courts.
Rule
Enter a search term or FR citation e.g.
88 FR 38230 FR 78782024-13208USDA09/05/24RULE0503-AA39SORN
Choosing an item from
full text search results
will bring you to those results. Pressing enter in the search box
will also bring you to search results.
Choosing an item from
suggestions
will bring you directly to the content.
This table of contents is a navigational tool, processed from the
headings within the legal text of Federal Register documents.
This repetition of headings to form internal navigation links
has no substantive legal effect.
Document page views are updated periodically throughout the day and are
cumulative counts for this document. Counts are subject to sampling,
reprocessing and revision (up or down) throughout the day.
Page views
307
as of
09/11/2026 at 8:15 am EDT
Other Formats
Enhanced Content - Other Formats
This document is also available in the following formats:
This document has been published in the Federal Register. Use the PDF linked in the document sidebar for the official electronic format.
AGENCY:
Mine Safety and Health Administration (MSHA), Labor.
ACTION:
Final rule; Technical amendment.
SUMMARY:
This technical amendment moves several definitions from subparts B, C, E, H, M, and R of 30 CFR part 56, and from subparts B, C, E, H, M and T of 30 CFR part 57 to the general definitions section in subpart A of 30 CFR parts 56 and 57 respectively. This action eliminates redundancy and potential confusion with multiple definitions. It provides the metal and nonmetal mining community a central location in the CFR where most definitions applicable to surface or underground metal and nonmetal mines can be found. Definitions that have a specific application to a particular subpart have not been moved to subpart A.
DATES:
Effective Date:
June 29, 2004.
FOR FURTHER INFORMATION CONTACT:
Marvin W. Nichols, Jr., Director, Office of Standards, Regulations and Variances, MSHA; 1100 Wilson Boulevard, Room 2350, Arlington, Virginia 22209-3939; telephone (202) 693-9440; facsimile (202) 693-9441; or e-mail:
nichols.marvin@DOL.gov.
This notice is available on the Internet at
http://www.msha.gov/REGSINFOR.HTM.
SUPPLEMENTARY INFORMATION:
I. Discussion of Changes
This technical amendment moves several definitions from subparts B, C, E, H, M and R of 30 CFR part 56; and subparts B, C, E, H, M and T of 30 CFR part 57 to the general definition section of subpart A of 30 CFR parts 56 and 57. This action eliminates redundancy and potential confusion with multiple definitions. It provides the metal and nonmetal mining community a central location in the CFR where most definitions applicable to surface or underground metal and nonmetal mines can be found. Definitions that have a specific application to a particular subpart have not been moved to subpart A.
II. Procedural Matters
Administrative Procedures Act
The minor revisions contained in this notice are technical and nonsubstantive in nature. Accordingly, pursuant to 5 U.S.C. 553(b)(B) of the Administrative Procedures Act (APA), it has been determined that the notice and comment procedures do not apply to this action. For the same reason, it has been determined that in accordance with 5 U.S.C. 553(d), there is good cause to make these changes effective on the date of publication in the
Federal Register
.
III. Part 56
To eliminate potential confusion and redundancy with the definitions, the definition for
Explosive
found in § 56.2 and § 56.6000, has been combined and moved to § 56.2, the general definitions section for 30 CFR part 56. The definitions for
berm
and
mobil equipment
have been moved to § 56.2. Accordingly, § 56.9000 has now been deleted since
berm
and
mobile equipment
were the only definitions in that section.
IV. Part 57
To eliminate potential confusion and redundancy with the definitions, the definitions for
Auxiliary fan
found in § 57.2 and § 57.22002,
Booster fan
found in § 57.2 and § 57.22002,
Combustible material
found in § 57.4000 and § 57.22002,
Mobile equipment
found in § 57.9000 and § 57.14000, and
Noncombustible material
found in § 57.4000 and § 57.22002, have been combined and moved to § 57.2, the general definitions section to 30 CFR part 57. The definitions for
berm
and
mobile equipment
have been moved to § 57.2. Accordingly, § 57.9000 has now been deleted since
berm
and
mobile equipment
were the only two definitions in that section.
Deputy Assistant Secretary of Labor for Mine Safety and Health.
For the reasons set out in the preamble, and under the authority of the Federal Mine Safety and Health Act of 1977, MSHA is amending chapter I, parts 56 and 57 of title 30 of the Code of Federal Regulations as follows:
PART 56—[AMENDED]
1. The authority citation for part 56 continues to read as follows:
The following definitions apply in this part. In addition definitions contained in any subpart of part 56 apply in that subpart. If inconsistent with the general definitions in this section, the definition in the subpart will apply in that subpart:
American Table of Distances
means the current edition of “The American Table of Distances for Storage of Explosives” published by the Institute of Makers of Explosives.
Approved
means tested and accepted for a specific purpose by a nationally recognized agency.
( printed page 38838)
Attended
means presence of an individual or continuous monitoring to prevent unauthorized entry or access.
Authorized person
means a person approved or assigned by mine management to perform a specific type of duty or duties or to be at a specific location or locations in the mine.
Barricaded
means obstructed to prevent the passage of persons, vehicles, or flying materials.
Barrier
means a material object, or objects that separates, keeps apart, or demarcates in a conspicuous manner such as cones, a warning sign, or tape.
Berm
means a pile or mound of material along an elevated roadway capable of moderating or limiting the force of a vehicle in order to impede the vehicle's passage over the bank of the roadway.
Blast area
means the area in which concussion (shock wave), flying material, or gases from an explosion may cause injury to persons. In determining the blast area, the following factors shall be considered:
(1) Geology or material to be blasted.
(2) Blast pattern.
(3) Burden, depth, diameter, and angle of the holes.
(4) Blasting experience of the mine.
(5) Delay system, powder factor, and pounds per delay.
(6) Type and amount of explosive material.
(7) Type and amount of stemming.
Blast site
means the area where explosive material is handled during loading, including the perimeter formed by the loaded blastholes and 50 feet (15.2 meters) in all directions from loaded holes. A minimum distance of 30 feet (9.1 meters) may replace the 50-foot (15.2-meter) requirement if the perimeter of loaded holes is demarcated with a barrier. The 50-foot (15.2-meter) and alternative 30-foot (9.1-meter) requirement also apply in all directions along the full depth of the hole.
Blasting agent
means any substance classified as a blasting agent by the Department of Transportation in 49 CFR 173.114(a) (44 FR 31182, May 31, 1979) which is incorporated by reference. This document is available for inspection at each Metal and Nonmetal Safety and Health District Office of the Mine Safety and Health Administration, and may be obtained from the U.S. Government Printing Office, Washington, DC 20402.
Blasting area
means the area near the blasting operations in which concussion or flying material can reasonably be expected to cause injury.
Blasting cap
means a detonator which is initiated by a safety fuse.
Blasting circuit
means the electrical circuit used to fire one or more electric blasting caps.
Blasting switch
means a switch used to connect a power source to a blasting circuit.
Booster
means any unit of explosive or blasting agent used for the purpose of perpetuating or intensifying an initial detonation.
Capped fuse
means a length of safety fuse to which a blasting cap has been attached.
Capped primer
means a package or cartridge of explosives which is specifically designed to transmit detonation to other explosives and which contains a detonator.
Circuit breaker
means a device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent setting without injury to itself when properly applied within its rating.
Combustible
means capable of being ignited and consumed by fire.
Combustible liquids
means liquids having a flash point at or above 100 °F (37.8 °C). They are divided into the following classes:
(1) Class II liquids—those having flash points at or above 100 °F (37.8 °C) and below 140 °F (60 °C).
(2) Class IIIA liquids—those having flash points at or above 140 °F (60 °C) and below 200 °F (93.4 °C).
(3) Class IIIB liquids—those having flash points at or above 200 °F (93.4 °C).
Combustible material
means a material that, in the form in which it is used and under the conditions anticipated, will ignite, burn, support combustion, or release flammable vapors when subjected to fire or heat. Wood, paper, rubber, and plastics are examples of combustible materials.
Company official
means a member of the company supervisory or technical staff.
Competent person
means a person having abilities and experience that fully qualify him to perform the duty to which he is assigned.
Conductor
means a material, usually in the form of a wire, cable, or bus bar, capable of carrying an electric current.
Delay connector
means a non-electric short interval delay device for use in delaying blasts which are initiated by detonating cord.
Detonating cord
means a flexible cord containing a solid core of high explosives.
Detonator
means any device containing a detonating charge that is used to initiate an explosive and includes but is not limited to blasting caps, electric blasting caps and nonelectric instantaneous or delay blasting caps.
Distribution box
means a portable apparatus with an enclosure through which an electric circuit is carried to one or more cables from a single incoming feed line, each cable circuit being connected through individual overcurrent protective devices.
Electric blasting cap
means a detonator designed for and capable of being initiated by means of an electric current.
Electrical grounding
means to connect with the ground to make the earth part of the circuit.
Employee
means a person who works for wages or salary in the service of an employer.
Employer
means a person or organization which hires one or more persons to work for wages or salary.
Emulsion
means an explosive material containing substantial amounts of oxidizers dissolved in water droplets, surrounded by an immiscible fuel.
Explosive
means any substance classified as an explosive by the Department of Transportation in 49 CFR 173.53, 173.88, and 173.100 which are incorporated by reference. Title 49 CFR is available for inspection at each Metal and Nonmetal Safety and Health district office of the Mine Safety and Health Administration, and may be obtained from the U.S. Government Printing Office, Washington, DC 20402.
Explosive material
means explosives, blasting agents, and detonators.
Face or bank
means that part of any mine where excavating is progressing or was last done.
Fire resistance rating
means the time, in minutes or hours, that an assembly of materials will retain its protective characteristics or structural integrity upon exposure to fire.
Flammable
means capable of being easily ignited and of burning rapidly.
Flammable gas
means a gas that will burn in the normal concentrations of oxygen in the air.
Flammable liquid
means a liquid that has a flash point below 100 °F (37.8 °C), a vapor pressure not exceeding 40 pounds per square inch (absolute) at 100 °F (37.8 °C), and is known as a Class I liquid.
Flash point
means the minimum temperature at which sufficient vapor is released by a liquid or solid to form a flammable vapor-air mixture at atmospheric pressure.
High potential
means more than 650 volts.
Highway
means any public street, public alley, or public road.
Hoist
means a power driven windlass or drum used for raising ore, rock, or other material from a mine, and for lowering or raising persons and material.
Igniter cord
means a fuse, cordlike in appearance, which burns progressively
( printed page 38839)
along its length with an external flame at the zone of burning, and is used for lighting a series of safety fuses in the desired sequence.
Insulated
means separated from other conducting surfaces by a dielectric substance permanently offering a high resistance to the passage of current and to disruptive discharge through the substance. When any substance is said to be insulated, it is understood to be insulated in a manner suitable for the conditions to which it is subjected. Otherwise, it is, within the purpose of this definition, uninsulated. Insulating covering is one means for making the conductor insulated.
Insulation
means a dielectric substance offering a high resistance to the passage of current and to a disruptive discharge through the substance.
Laminated partition
means a partition composed of the following material and minimum nominal dimensions:
1/2
-inch-thick plywood,
1/2
-inch-thick gypsum wallboard,
1/8
-inch-thick low carbon steel, and
1/4
-inch-thick plywood, bonded together in that order (IME-22 Box). A laminated partition also includes alternative construction materials described in the Institute of Makers of Explosives (IME) Safety Library Publication No. 22, “Recommendations for the Safe Transportation of Detonators in a Vehicle with other Explosive Materials,” (May 1993), and the “Generic Loading Guide for the IME-22 Container,” (October 1993). This incorporation by reference has been approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies are available at MSHA, 1100 Wilson Blvd., Room 2436, Arlington, Virginia 22209-3939, and at all Metal and Nonmetal Mine Safety and Health district offices, or available for inspection at the Office of the Federal Register, 800 North Capitol Street, NW., 7th Floor, suite 700, Washington, DC.
Lay
means the distance parallel to the axis of the rope in which a strand makes one complete turn about the axis of the rope.
Loading
means placing explosive material either in a blasthole or against the material to be blasted.
Low potential
means 650 volts or less.
Magazine
means a facility for the storage of explosives, blasting agents, or detonators.
Major electrical installation
means an assemblage of stationary electrical equipment for the generation, transmission, distribution, or conversion of electrical power.
Mantrip
means a trip on which persons are transported to and from a work area.
Mill
includes any ore mill, sampling works, concentrator, and any crushing, grinding, or screening plant used at, and in connection with, an excavation or mine.
Misfire
means the complete or partial failure of a blasting charge to explode as planned.
Mobile equipment
means wheeled, skid-mounted, track-mounted, or rail-mounted equipment capable of moving or being moved.
Multipurpose dry-chemical fire extinguisher
means an extinguisher having a rating of at least 2-A:10-B:C and containing a nominal 4.5 pounds or more of dry-chemical agent.
Noncombustible material
means a material that, in the form in which it is used and under the conditions anticipated, will not ignite, burn, support combustion, or release flammable vapors when subjected to fire or heat. Concrete, masonry block, brick, and steel are examples of noncombustible materials.
Non-electric delay blasting cap
means a detonator with an integral delay element and capable of being initiated by miniaturized detonating cord.
Overburden
means material of any nature, consolidated or unconsolidated, that overlies a deposit of useful materials or ores that are to be mined.
Overload
means that current which will cause an excessive or dangerous temperature in the conductor or conductor insulation.
Permissible
means a machine, material, apparatus, or device that has been investigated, tested, and approved by the Bureau of Mines or the Mine Safety and Health Administration and is maintained in permissible condition.
Potable water
means water which shall meet the applicable minimum health requirements for drinking water established by the State or community in which the mine is located or by the Environmental Protection Agency in 40 CFR part 141, pages 169-182 revised as of July 1, 1977. Where no such requirements are applicable, the drinking water provided shall conform with the Public Health Service Drinking Water Standards, 42 CFR part 72, subpart J, pages 527-533, revised as of October 1, 1976. Publications to which references are made in this definition are hereby made a part hereof. These incorporated publications are available for inspection at each Metal and Nonmetal Mine Safety and Health District Office of the Mine Safety and Health Administration.
Powder chest
means a substantial, nonconductive portable container equipped with a lid and used at blasting sites for explosives other than blasting agents.
Primer
means a unit, package, or cartridge of explosives used to initiate other explosives or blasting agents, and which contains a detonator.
Reverse-current protection
means a method or device used on direct-current circuits or equipment to prevent the flow of current in the reverse direction.
Rock fixture
means any tensioned or nontensioned device or material inserted into the ground to strengthen or support the ground.
Roll protection
means a framework, safety canopy or similar protection for the operator when equipment over-turns.
Safety can
means an approved container, of not over five gallons capacity, having a spring-closing lid and spout cover.
Safety fuse
means a flexible cord containing an internal burning medium by which fire is conveyed at a continuous and uniform rate for the purpose of firing blasting caps or a black powder charge.
Safety switch
means a sectionalizing switch that also provides shunt protection in blasting circuits between the blasting switch and the shot area.
Scaling
means removal of insecure material from a face or highwall.
Secondary safety connection
means a second connection between a conveyance and rope, intended to prevent the conveyance from running away or falling in the event the primary connection fails.
Shaft
means a vertical or inclined shaft, a slope, incline or winze.
Short circuit
means an abnormal connection of relatively low resistance, whether made accidentally or intentionally, between two points of different potential in a circuit.
Slurry (as applied to blasting).
See “Water gel.”
Storage facility
means the entire class of structures used to store explosive materials. A “storage facility” used to store blasting agents corresponds to a BATF Type 4 or 5 storage facility.
Storage tank
means a container exceeding 60 gallons in capacity used for the storage of flammable or combustible liquids.
Stray current
means that portion of a total electric current that flows through paths other than the intended circuit.
Substantial construction
means construction of such strength, material, and workmanship that the object will withstand all reasonable shock, wear, and usage, to which it will be subjected.
( printed page 38840)
Suitable
means that which fits, and has the qualities or qualifications to meet a given purpose, occasion, condition, function, or circumstance.
Travelway
means a passage, walk or way regularly used and designated for persons to go from one place to another.
Water gel
or
Slurry
(as applied to blasting) means an explosive or blasting agent containing substantial portions of water.
Wet drilling
means the continuous application of water through the central hole of hollow drill steel to the bottom of the drill hole.
Working place
means any place in or about a mine where work is being performed.
The following definitions apply to this part. In addition definitions contained in any subpart of part 57 apply in that subpart. If inconsistent with the general definitions in this section, the definition in the subpart will apply in that subpart:
Abandoned areas
means areas in which work has been completed, no further work is planned, and travel is not permitted.
Abandoned mine
means all work has stopped on the mine premises and an office with a responsible person in charge is no longer maintained at the mine.
Abandoned workings
means deserted mine areas in which further work is not intended.
Active workings
means areas at, in, or around a mine or plant where men work or travel.
American Table of Distances
means the current edition of “The American Table of Distances for Storage of Explosives” published by the Institute of Makers of Explosives.
Approved
means tested and accepted for a specific purpose by a nationally recognized agency.
Attended
means presence of an individual or continuous monitoring to prevent unauthorized entry or access. In addition, areas containing explosive material at underground areas of a mine can be considered attended when all access to the underground areas of the mine is secured from unauthorized entry. Vertical shafts shall be considered secure. Inclined shafts or adits shall be considered secure when locked at the surface.
Authorized person
means a person approved or assigned by mine management to perform a specific type of duty or duties or to be at a specific location or locations in the mine.
Auxilary fan
means a fan used to deliver air to a working place off the main airstream; generally used with ventilation tubing.
Barricaded
means obstructed to prevent the passage of persons, vehicles, or flying materials.
Barrier
means a material object, or objects that separates, keeps apart, or demarcates in a conspicuous manner such as cones, a warning sign, or tape.
Berm
means a pile or mound of material along an elevated roadway capable of moderating or limiting the force of a vehicle in order to impede the vehicle's passage over the bank of the roadway.
Blast area
means the area in which concussion (shock wave), flying material, or gases from an explosion may cause injury to persons. In determining the blast area, the following factors, shall be considered:
(1) Geology or material to be blasted.
(2) Blast pattern.
(3) Burden, depth, diameter, and angle of the holes.
(4) Blasting experience of the mine.
(5) Delay system, powder factor, and pounds per delay.
(6) Type and amount of explosive material.
(7) Type and amount of stemming.
Blast site
means the area where explosive material is handled during loading, including the perimeter formed by the loaded blastholes and 50 feet (15.2 meters) in all directions from loaded holes. A minimum distance of 30 feet (9.1 meters) may replace the 50-foot (15.2-meter) requirement if the perimeter of loaded holes is demarcated with a barrier. The 50-foot (15.2-meter) and alternative 30-foot (9.1-meter) requirements also apply in all directions along the full depth of the hole. In underground mines, at least 15 feet (4.6 meters) of solid rib, pillar, or broken rock can be substituted for the 50-foot (15.2-meter) distance. In underground mines utilizing a block-caving system or similar system, at least 6 feet (1.8 meters) of solid rib or pillar, including concrete reinforcement of at least 10 inches (254 millimeters), with overall dimensions of not less than 6 feet (1.8 meters) may be substituted for the 50-foot (15.2-meter) distance requirement.
Blasting agent
means any substance classified as a blasting agent by the Department of Transportation in 49 CFR 173.114(a) (44 FR 31182, May 31, 1979) which is incorporated by reference. This document is available for inspection at each Metal and Nonmetal Mine Safety and Health District Office of the Mine Safety and Health Administration, and may be obtained from the U.S. Government Printing Office, Washington, DC 20402.
Blasting area
means the area near blasting operations in which concussion or flying material can reasonably be expected to cause injury.
Blasting cap
means a detonator which is initiated by a safety fuse.
Blasting circuit
means the electrical circuit used to fire one or more electric blasting caps.
Blasting
switch means a switch used to connect a power source to a blasting circuit.
Blowout
means a sudden, violent, release of gas or liquid due to the reservoir pressure in a petroleum mine.
Booster
means any unit of explosive or blasting agent used for the purpose of perpetuating or intensifying an initial detonation.
Booster fan
means a fan installed in the main airstream or a split of the main airstream to increase airflow through a section or sections of a mine.
Capped fuse
means a length of safety fuse to which a blasting cap has been attached.
Capped primer
means a package or cartridge of explosives which is specifically designed to transmit detonation to other explosives and which contains a detonator.
( printed page 38841)
Circuit breaker
means a device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent setting without injury to itself when properly applied within its rating.
Combustible
means capable of being ignited and consumed by fire.
Combustible material
means a material that, in the form in which it is used and under the conditions anticipated, will ignite, burn, support combustion or release flammable vapors when subjected to fire or heat. Wood, paper, rubber, and plastics are examples of combustible materials.
Company official
means a member of the company supervisory or technical staff.
Competent person
means a person having abilities and experience that fully qualify him to perform the duty to which he is assigned.
Conductor
means a material, usually in the form of a wire, cable, or bus bar, capable of carrying an electric current.
Delay connector
means a nonelectric short interval delay device for use in delaying blasts which are initiated by detonating cord.
Detonating cord
means a flexible cord containing a solid core of high explosives.
Detonator
means any device containing a detonating charge that is used to initiate an explosive and includes but is not limited to blasting caps, electric blasting caps and non-electric instantaneous or delay blasting caps.
Distribution box
means a portable apparatus with an enclosure through which an electric circuit is carried to one or more cables from a single incoming feed line; each cable circuit being connected through individual overcurrent protective devices.
Electric blasting cap
means a detonator designed for and capable of being initiated by means of an electric current.
Electrical grounding
means to connect with the ground to make the earth part of the circuit.
Employee
means a person who works for wages or salary in the service of an employer.
Employer
means a person or organization which hires one or more persons to work for wages or salary.
Emulsion
means an explosive material containing substantial amounts of oxidizers dissolved in water droplets, surrounded by an immiscible fuel.
Escapeway
means a passageway by which persons may leave a mine.
Explosive
means any substance classified as an explosive by the Department of Transportation in 49 CFR 173.53, 173.88 and 173.100 which are incorporated by reference. Title 49 CFR is available for inspection at each Metal and Nonmetal Mine Safety and Health District Office of the Mine Safety and Health Administration, and may be obtained from the U.S. Government Printing Office, Washington, DC 20402.
Face or bank
means that part of any mine where excavating is progressing or was last done.
Fire resistance rating
means the time, in minutes or hours, that an assembly of materials will retain its protective characteristics or structural integrity upon exposure to fire.
Flame spread rating
means the numerical designation that indicates the extent flame will spread over the surface of a material during a specified period of time.
Flammable
means capable of being easily ignited and of burning rapidly.
Flammable gas
means a gas that will burn in the normal concentrations of oxygen in the air.
Flammable liquid
a liquid that has a flash point below 100 °F (37.8 °C), a vapor pressure not exceeding 40 pounds per square inch (absolute) at 100 °F (37.8 °C), and is known as a Class I liquid.
Flash point
means the minimum temperature at which sufficient vapor is released by a liquid or solid to form a flammable vapor-air mixture at atmospheric pressure.
Geological area
means an area characterized by the presence of the same ore bodies, the same stratigraphic sequence of beds, or the same ore-bearing geological formation.
Highway
means any public street, public alley or public road.
High potential
means more than 650 volts.
Hoist
means a power driven windlass or drum used for raising ore, rock, or other material from a mine, and for lowering or raising persons and material.
Igniter cord
means a fuse, cordlike in appearance, which burns progressively along its length with an external flame at the zone of burning, and is used for lighting a series of safety fuses in the desired sequence.
Insulated
means separated from other conducting surfaces by a dielectric substance permanently offering a high resistance to the passage of current and to disruptive discharge through the substance. When any substance is said to be insulated, it is understood to be insulated in a manner suitable for the conditions to which it is subjected. Otherwise, it is, within the purpose of this definition, uninsulated. Insulating covering is one means for making the conductor insulated.
Insulation
means a dielectric substance offering a high resistance to the passage of current and to a disruptive discharge through the substance.
Laminated partition
a partition composed of the following material and minimum nominal dimensions:
1/2
-inch-thick plywood,
1/2
-inch-thick gypsum wallboard,
1/8
-inch-thick low carbon steel, and
1/4
-inch-thick plywood, bonded together in that order (IME-22 Box). A laminated partition also includes alternative construction materials described in the Institute of Makers of Explosives (IME) Safety Library Publication No. 22, “Recommendations for the Safe Transportation of Detonators in a Vehicle with other Explosive Materials,” (May 1993), and the “Generic Loading Guide for the IME-22 Container,” (October 1993). This incorporation by reference has been approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies are available at MSHA, 1100 Wilson Blvd., Room 2436, Arlington, Virginia 22209-3939, and at all Metal and Nonmetal Mine Safety and Health district offices, or available for inspection at the Office of the Federal Register, 800 North Capitol Street, NW., 7th Floor, suite 700, Washington, DC.
Lay
means the distance parallel to the axis of the rope in which a strand makes one complete turn about the axis of the rope.
Loading
means placing explosive material either in a blasthole or against the material to be blasted.
Low potential
means 650 volts or less.
Magazine
means a facility for the storage of explosives, blasting agents, or detonators.
Main fan
means a fan that controls the entire airflow of the mine, or the airflow of one of the major air circuits.
Major electrical installation
means an assemblage of stationary electrical equipment for the generation, transmission, distribution, or conversion of electrical power.
Mantrip
means a trip on which persons are transported to and from a work area.
Mill
includes any ore mill, sampling works, concentrator, and any crushing, grinding, or screening plant used at, and in connection with, an excavation or mine.
Mine atmosphere
means any point at least 12 inches away from the back, face, rib, and floor in any mine; and additionally, in a Category IV mine, at least 3 feet laterally away from the collar
( printed page 38842)
of a borehole which releases gas into a mine.
Mine opening
means any opening or entrance from the surface into a mine.
Misfire
means the complete or partial failure of a blasting charge to explode as planned.
Mobile equipment
means wheeled, skid-mounted, track-mounted, or rail-mounted equipment capable of moving or being moved.
Multipurpose dry-chemical fire extinguisher
means an extinguisher having a rating of at least 2-A:10-B:C and containing a nominal 4.5 pounds or more of dry-chemical agent.
Noncombustible material
means a material that, in the form in which it is used and under the conditions anticipated, will not ignite, burn, support combustion, or release flammable vapors when subjected to fire or heat. Concrete, masonry block, brick, and steel are examples of noncombustible materials.
Non-electric delay blasting cap
means a detonator with an integral delay element and capable of being initiated by miniaturized detonating cord.
Outburst
means the sudden, violent release of solids and high-pressure occluded gases, including methane in a domal salt mine.
Overburden
means material of any nature, consolidated or unconsolidated, that overlies a deposit of useful materials or ores that are to be mined.
Overload
means that current which will cause an excessive or dangerous temperature in the conductor or conductor insulation.
Permissible
means a machine, material, apparatus, or device which has been investigated, tested, and approved by the Bureau of Mines or the Mine Safety and Health Administration, and is maintained in permissible condition.
Potable water
means water which shall meet the applicable minimum health requirements for drinking water established by the State or community in which the mine is located or by the Environmental Protection Agency in 40 CFR part 141, pages 169-182 revised as of July 1, 1977. Where no such requirements are applicable, the drinking water provided shall conform with the Public Health Service Drinking Water Standards, 42 CFR part 72, subpart J, pages 527-533, revised as of October 1, 1976. Publications to which references are made in this definition are hereby made a part hereof. These incorporated publications are available for inspection at each Metal and Nonmetal Mine Safety and Health District Office of the Mine Safety and Health Administration.
Powder chest
means a substantial, nonconductive portable container equipped with a lid and used at blasting sites for explosives other than blasting agents.
Primer
means a unit, package, or cartridge of explosives used to initiate other explosives or blasting agents, and which contains a detonator.
Reverse-current protection
means a method or device used on direct-current circuits or equipment to prevent the flow of current in a reverse direction.
Rock burst
means a sudden and violent failure of overstressed rock resulting in the instantaneous release of large amounts of accumulated energy. Rock burst does not include a burst resulting from pressurized mine gases.
Rock fixture
means any tensioned or nontensioned device or material inserted into the ground to strengthen or support the ground.
Roll protection
means a framework, safety canopy or similar protection for the operator when equipment overturns.
Safety can
means an approved container, of not over 5 gallons capacity, having a spring-closing lid and spout cover.
Safety fuse
means a flexible cord containing an internal burning medium by which fire is conveyed at a continuous and uniform rate for the purpose of firing blasting caps or a black powder charge.
Safety switch
means a sectionalizing switch that also provides shunt protection in blasting circuits between the blasting switch and the shot area.
Scaling
means removal of insecure material from a face or highwall.
Secondary safety connection
means a second connection between a conveyance and rope, intended to prevent the conveyance from running away or falling in the event the primary connection fails.
Shaft
means a vertical or inclined shaft, a slope, incline, or winze.
Short circuit
means an abnormal connection of relatively low resistance, whether made accidentally or intentionally, between two points of difference potential in a circuit.
Slurry
(as applied to blasting). See “Water gel.”
Storage facility
means the entire class of structures used to store explosive materials. A “storage facility” used to store blasting agents corresponds to a BATF Type 4 or 5 storage facility.
Storage tank
means a container exceeding 60 gallons in capacity used for the storage of flammable or combustible liquids.
Stray current
means that portion of a total electric current that flows through paths other than the intended circuit.
Substantial construction
means construction of such strength, material, and workmanship that the object will withstand all reasonable shock, wear, and usage to which it will be subjected.
Suitable
means that which fits, and has the qualities or qualifications to meet a given purpose, occasion, condition, function, or circumstance.
Travelway
means a passage, walk or way regularly used and designated for persons to go from one place to another.
Water gel or Slurry
(as applied to blasting) means an explosive or blasting agent containing substantial portions of water.
Wet drilling
means the continuous application of water through the central hole of hollow drill steel to the bottom of the drill hole.
Working level
(WL) means any combination of the short-lived radon daughters in one liter of air that will result in ultimate emission of 1.3×105
MeV (million electron volts) of potential alpha energy, and exposure to these radon daughters over a period of time is expressed in terms of “working level months” (WLM). Inhalation of air containing a radon daughter concentration of 1 WL for 173 hours results in an exposure of 1 WLM.”
Working place
means any place in or about a mine where work is being performed.