Published Document: C6-4919 (71 FR 36394)

This document has been published in the Federal Register. Use the PDF linked in the document sidebar for the official electronic format.

( printed page 36394)

Correction

In proposed rule document 06-4919 beginning on page 33804 in the issue of Monday, June 12, 2006, make the following corrections:

1. On page 33808, in Table 1, in the table heading, in the first line, “>19” should read “≤19”.

2. On page 33809, in Table 3, in the second column, in the third entry, “HP≤500” should read “HP≥500”.

3. On the same page, in the same table, in the same column, in the fifth entry, “HP≥500” should read “HP<500”.

4. On pages 33810 and 33811, Table 4 is being reprinted in its entirety to read as follows:

Table 4.—Emission Standards for Stationary RICE ≤ 500 HP Located at Major Sources of HAP Emissions and Stationary RICE Located at Area Sources of HAP Emissions

Engine type and fuel Maximum engine power Manufacture date a Emission standards
Existing All Fuels and All Types All Sizes No Emission Reduction.
New/Reconstructed SI ≤25 HP January 1, 2008 Meet 40 CFR part 60 subpart JJJJ.
New/Reconstructed SI Gasoline and Rich Burn LPG 25<HP<500 HP≥500 January 1, 2008 July 1, 2007 Meet 40 CFR part 60 subpart JJJJ.
New/Reconstructed Non-Emergency SI Natural Gas 25<HP<500 a January 1, 2008 1.0 g/HP-hr NMHC.
and
New/Reconstructed Non-Emergency SI Lean Burn LPG b January 1, 2011 0.7 g/HP-hr NMHC.
New/Reconstructed Non-Emergency SI Natural Gas HP≥500 July 1, 2007 1.0 g/HP-hr NMHC
and
New/Reconstructed Non-Emergency SI Lean Burn LPG July 1, 2010 0.7 g/HP-hr NMHC.
New/Reconstructed Non-Emergency SI 4SLB at Major Sources (except landfill and digester gas) b 250<HP ≤500 January 1, 2008 93% CO Reduction or 14 ppmvd formaldehyde.
CI All Fuels All Sizes 2007+ Model Year Meet 40 CFR part 60 subpart IIII.
Landfill/Digester Gas HP<500 HP≥500 January 1, 2008 July 1, 2007 1.0 g/HP-hr NMHC. 1.0 g/HP-hr NMHC.
Emergency SI All Sizes January 1, 2009 1.0 g/HP-hr NMHC.
a  Stationary SI natural gas and lean burn LPG engines between 19 and 37 KW (25 and 50 HP) may comply with the requirements of Table 2 of this preamble, instead of this table, as applicable.
b  New and reconstructed non-emergency 4SLB engines at major sources with a site rating between 250 and 500 HP are not required to meet the 1.0 and 0.7 g/HP-hr NMHC emission standards.
( printed page 36395)

Table 3 to Subpart ZZZZ of Part 63 [Corrected]

5. On page 33844, in Table 3 to Subpart ZZZZ of Part 63, in the table heading, in the second line,“>500 HP” should read “≤500 HP”.

6. On page 33845, in the same table, in the table heading, in the second line,“>500 HP” should read “≤500 HP”.

[FR Doc. C6-4919 Filed 6-23-06; 8:45 am]

BILLING CODE 1505-01-D