This site displays a prototype of a “Web 2.0” version of the daily
Federal Register. It is not an official legal edition of the Federal
Register, and does not replace the official print version or the official
electronic version on GPO’s govinfo.gov.
The documents posted on this site are XML renditions of published Federal
Register documents. Each document posted on the site includes a link to the
corresponding official PDF file on govinfo.gov. This prototype edition of the
daily Federal Register on FederalRegister.gov will remain an unofficial
informational resource until the Administrative Committee of the Federal
Register (ACFR) issues a regulation granting it official legal status.
For complete information about, and access to, our official publications
and services, go to
About the Federal Register
on NARA's archives.gov.
The OFR/GPO partnership is committed to presenting accurate and reliable
regulatory information on FederalRegister.gov with the objective of
establishing the XML-based Federal Register as an ACFR-sanctioned
publication in the future. While every effort has been made to ensure that
the material on FederalRegister.gov is accurately displayed, consistent with
the official SGML-based PDF version on govinfo.gov, those relying on it for
legal research should verify their results against an official edition of
the Federal Register. Until the ACFR grants it official status, the XML
rendition of the daily Federal Register on FederalRegister.gov does not
provide legal notice to the public or judicial notice to the courts.
Rule
Enter a search term or FR citation e.g.
88 FR 38230 FR 78782024-13208USDA09/05/24RULE0503-AA39SORN
Choosing an item from
full text search results
will bring you to those results. Pressing enter in the search box
will also bring you to search results.
Choosing an item from
suggestions
will bring you directly to the content.
This table of contents is a navigational tool, processed from the
headings within the legal text of Federal Register documents.
This repetition of headings to form internal navigation links
has no substantive legal effect.
Document page views are updated periodically throughout the day and are
cumulative counts for this document. Counts are subject to sampling,
reprocessing and revision (up or down) throughout the day.
Page views
62
as of
11/11/2026 at 4:15 am EST
Other Formats
Enhanced Content - Other Formats
This document is also available in the following formats:
This document has been published in the Federal Register. Use the PDF linked in the document sidebar for the official electronic format.
AGENCY:
Federal Aviation Administration (FAA), Department of Transportation (DOT).
ACTION:
Final rule.
SUMMARY:
The FAA is adopting a new airworthiness directive (AD) for certain Raytheon (Beech) Model 400 and 400A series airplanes. This AD requires, among other actions, reviewing the airplane logbook to determine whether certain generator control unit (GCU) installation kits are installed, and replacing any incorrect GCU. This AD results from reports of over-voltage conditions of the direct current (DC) starter generator. We are issuing this AD to prevent such over-voltage conditions due to the incompatibility between certain GCUs, which could result in the loss of normal electrical power, damage to some electrical components, or blown fuses during flight, and consequent unrecoverable loss of some or all essential equipment.
DATES:
This AD becomes effective September 5, 2006.
The Director of the Federal Register approved the incorporation by reference of a certain publication listed in the AD as of September 5, 2006.
ADDRESSES:
You may examine the AD docket on the Internet at
http://dms.dot.gov
or in person at the Docket Management Facility, U.S. Department of Transportation, 400 Seventh Street, SW., Nassif Building, Room PL-401, Washington, DC.
Contact Raytheon Aircraft Company, Department 62, P.O. Box 85, Wichita, Kansas 67201-0085, for service information identified in this AD.
You may examine the airworthiness directive (AD) docket on the Internet at
http://dms.dot.gov
or in person at the Docket Management Facility office between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. The Docket Management Facility office (telephone (800) 647-5227) is located on the plaza level of the Nassif Building at the street address stated in the
ADDRESSES
section.
Discussion
The FAA issued a notice of proposed rulemaking (NPRM) to amend 14 CFR part 39 to include an AD that would apply to certain Raytheon (Beech) Model 400 and 400A series airplanes. That NPRM was published in the
Federal Register
on May 9, 2006 (71 FR 26877). That NPRM proposed to require, among other actions, reviewing the airplane logbook to determine whether certain generator control unit (GCU) installation kits are installed, and replacing any incorrect GCU.
Comments
We provided the public the opportunity to participate in the development of this AD. We received no comments on the NPRM or on the determination of the cost to the public.
Conclusion
We have carefully reviewed the available data and determined that air safety and the public interest require adopting the AD as proposed.
Costs of Compliance
There are about 43 airplanes of the affected design in the worldwide fleet. This AD will affect about 40 airplanes of U.S. registry. The required inspection will take about 1 work hour per airplane, at an average labor rate of $80 per work hour. Based on these figures, the estimated cost of the AD for U.S. operators is $3,200, or $80 per airplane.
Authority for This Rulemaking
Title 49 of the United States Code specifies the FAA's authority to issue rules on aviation safety. Subtitle I, Section 106, describes the authority of the FAA Administrator. Subtitle VII, Aviation Programs, describes in more detail the scope of the Agency's authority.
We are issuing this rulemaking under the authority described in Subtitle VII, Part A, Subpart III, Section 44701, “General requirements.” Under that section, Congress charges the FAA with promoting safe flight of civil aircraft in air commerce by prescribing regulations for practices, methods, and procedures the Administrator finds necessary for safety in air commerce. This regulation is within the scope of that authority because it addresses an unsafe condition that is likely to exist or develop on products identified in this rulemaking action.
Regulatory Findings
We have determined that this AD will not have federalism implications under Executive Order 13132. This AD will not have a substantial direct effect on the States, on the relationship between the national government and the States, or on the distribution of power and responsibilities among the various levels of government.
For the reasons discussed above, I certify that this AD:
(2) Is not a “significant rule” under DOT Regulatory Policies and Procedures (44 FR 11034, February 26, 1979); and
(3) Will not have a significant economic impact, positive or negative, on a substantial number of small entities under the criteria of the Regulatory Flexibility Act.
We prepared a regulatory evaluation of the estimated costs to comply with this AD and placed it in the AD docket. See the
ADDRESSES
section for a location to examine the regulatory evaluation.
(c) This AD applies to the airplanes identified in Table 1 of this AD, certificated in any category.
Table 1.—Applicability
Raytheon (Beech) model—
Serials—
On which—
(1) 400 series airplanes
RJ-1 through RJ-65 inclusive
Kit part number (P/N) 128-3004-1 P or 128-3004-3 P has been incorporated (Lucas Aerospace/Goodrich Direct Current (DC) Starter Generator).
(2) 400A series airplanes
RK-1 through RK-23 inclusive
Kit P/N 128-3004-1 P or 128-3004-3 P has been incorporated (Lucas Aerospace/Goodrich DC Starter Generator).
Unsafe Condition
(d) This AD results from reports of over-voltage conditions of the DC starter generator. We are issuing this AD to prevent over-voltage conditions of the DC starter generator due to the incompatibility between certain generator control units (GCUs), which could result in the loss of normal electrical power, damage to some electrical components, or blown fuses during flight, and consequent unrecoverable loss of some or all essential equipment.
Compliance
(e) You are responsible for having the actions required by this AD performed within the compliance times specified, unless the actions have already been done.
( printed page 43041)
Service Bulletin
(f) The term “service bulletin,” as used in this AD, means the Accomplishment Instructions of Raytheon Service Bulletin SB 24-3713, dated November 2005.
Review of Logbook
(g) Within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first, review the airplane logbook to determine whether GCU installation kit, P/N 128-3001-1 P or 128-3001-3 P, is installed, in accordance with the service bulletin.
Installation Kit Not Found Installed: Replacement of Shinko GCUs
(h) If no GCU installation kit, P/N 128-3001-1 P or 128-3001-3 P, is found installed or if the kit P/N cannot be conclusively determined during the review required by paragraph (g) of this AD: Within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first, replace the Shinko GCUs with new Lucas Aerospace/Goodrich GCUs (installation kit P/N 128-3001-1 P or 128-3001-3 P), in accordance with the service bulletin.
Installation Kit Found Installed: Inspections of GCUs and Current Sense Transformers and Replacement of Transformers as Applicable
(i) If any GCU installation kit, P/N 128-3001-1 P or 128-3001-3 P is found installed during the review required by paragraph (g) of this AD: Within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first, inspect to determine the P/N of both GCUs, in accordance with the service bulletin; and at the times specified in Table 2 of this AD, do the applicable action(s) in that table.
Table 2.—Inspection and Replacement of Current Sense Transformers
If—
Then, within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first—
If—
Then—
(1) Both GCUs have P/N 45AS88801-19 or -25
Inspect to determine the P/N of both current sense transformers on the lower inboard quadrant of the left-hand and right-hand engine inlets, in accordance with the service bulletin
Both current sense transformers have P/N 45AS88801-21
Either current sense transformer is not identified with P/N 45AS88801-21
No further action is required by this AD.
Within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first, replace the current sense transformer with a new transformer, P/N 45AS88801-21, in accordance with the service bulletin.
(2) Either GCU does not have P/N 45AS88801-19 or -25
Replace the GCU with a new GCU, P/N 45AS88801-19 or -25, and inspect to determine the P/N of both current sense transformers on the lower inboard quadrant of the left-hand and right-hand engine inlets, in accordance with the service bulletin
Both current sense transformers have P/N 45AS88801-21
Either current sense transformer is not identified with P/N 45AS88801-21
No further action is required by this AD.
Within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first, replace the current sense transformer with a new transformer, P/N 45AS88801-21, in accordance with the service bulletin.
Alternative Methods of Compliance (AMOCs)
(j)(1) The Manager, Wichita Aircraft Certification Office, FAA, has the authority to approve AMOCs for this AD, if requested in accordance with the procedures found in 14 CFR 39.19.
(2) Before using any AMOC approved in accordance with § 39.19 on any airplane to which the AMOC applies, notify the appropriate principal inspector in the FAA Flight Standards Certificate Holding District Office.
Material Incorporated by Reference
(k) You must use Raytheon Service Bulletin SB 24-3713, dated November 2005, to perform the actions that are required by this AD, unless the AD specifies otherwise. The Director of the Federal Register approved the incorporation by reference of this document in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Contact Raytheon Aircraft Company, Department 62, P.O. Box 85, Wichita, Kansas 67201-0085, for a copy of this service information. You may review copies at the Docket Management Facility, U.S. Department of Transportation, 400 Seventh Street, SW., Room PL-401, Nassif Building, Washington, DC; on the Internet at
http://dms.dot.gov;
or at the National Archives and Records Administration (NARA). For information on the availability of this material at the NARA, call (202) 741-6030, or go to
http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.
Issued in Renton, Washington, on July 20, 2006.
Ali Bahrami,
Manager, Transport Airplane Directorate, Aircraft Certification Service.